Product Description:
Sewer Shield® 100 is the first product to offer 98% acid resistance, and is the highest overall chemical resistant coating on the market. We designed this coating for the heaviest and toughest environments. Unlike the “green” light bulbs that release mercury into the soil, our products are made from inert materials and have zero VOC’s which means we do not harm the soil, water or air, a truly green product. |
Sewer Shield® 100 is a 100% solids, solvent free, low odor, epoxy system, impervious to a wide variety of acids, solvents, caustic solutions, oils, grease and many other chemicals. Sewer Shield® 100 is specially formulated for various setting times and with virtually no odor, making it the ideal protection system for use in the food, dairy, meat beverage, brewery, and chemical industries. Sewer Shield 100, when cured, provides an impervious, hygienic, easy to clean surface. Its unique formula, which incorporates special adhesion promoters and stress recovering additives, provides a tenacious bond to most surfaces including damp concrete, while also providing ample resilience to resist most cracking from thermal or physical abuse. Sewer Shield® 100 is excellent as a lining system against chemical attack to walls, sumps, trenches, pits and is extremely effective in manholes and below-ground wastewater protection.
Warranty:
Sewer Shield® 100 is available
with a 15 year product warranty. Please contact Environmental
Coatings for details.
Application:
Sewer Shield® 100 is
applied by trowel to a thickness of 1/8"( up to 1/4") in one
application, which is then smoothed out by using a short
nap roller moistened with a solvent and back rolled over
the liner. This will flatten the liner and give it a smooth
finish. It's self-priming capabilities and tolerance for
damp surfaces offers the installer many labor saving steps
as well as less shut down time due to the fact that Sewer
Shield® 100 has very low odor and no solvent. No special
precautions are necessary to help contain any odor or solvent
smell, often found in many other systems.
Sewer Shield® 100 is ideal for smoothing out pitted concrete walls, especially where a smooth, impervious surface is required. Further crack resistance due to concrete cracking can be enhanced by applying our Sewer Shield® Caulk 100 over cracks and followed by the application of Sewer Shield® 100.
Coverage:
Coverage is dependent on
the texture of the substrate. The average rate per gallon
is 12.8 square feet at 1/8" thick.
Setting Times:
Sewer Shield® 100 is available in the following setting
times:
Sewer Shield® 100 for normal ambient temperature.
Sewer Shield® FS (fast set) for fast setting times at ambient
temperatures.
Sewer Shield® XFS (extra fast set) for extra fast setting
times at ambient temperatures.
Sewer Shield® CS (cold
set) for temperatures down to 35°F.
Colors:
Sewer Shield® 100 is supplied
in the following colors: Gray, Beige, and White. Special
colors are available upon request.
Packaging and Mixing:
Sewer Shield® 100 is supplied in either a pre-measured one-gallon
pack or as a standard three-gallon pack. Pour the contents
of Part B into Part A and mix thoroughly with either a low
speed drill (700 rpm) or a bucket mixer to a uniform consistency
for approximately one minute, then add the pre-measured
bag of Sewer Fill and mix again, making sure the sides and
bottom are scraped. If a mixing paddle is too small, it will not
give a uniform mix and an incomplete cure will result together
with wet spots. Over mixing with a high-speed drill will
shorten the pot life as well as introduce excess air into
the mix.
Priming:
Sewer Shield® 100 is self
priming on new and existing concrete. However, if Sewer
Shield® is to be applied over "green concrete," then our
Corro-Cure (a slow setting primer) must be used within 24
hours from pour, after which Sewer Shield® can be applied.
New and existing concrete exposed to full sun must have a coat of Sewer Shield® primer to stop out-gassing which creates bubbles in the finish coat.
| MSDS Sheet | Product Data |
Description:
Sewer Shield® 150 Trowelable
is the next generation of 100% solids, solvent free, low
odor, environmentally friendly, epoxy liner system. It is
impervious to a wide variety of acids, caustic solutions,
oils, grease and many other chemicals. Sewer Shield® 150
Trowel is particularly resistant to Sulfuric Acid up to
concentrations of 50%. No special precautions are necessary
to help contain any odor or solvent smell often found in
many other liner systems.
Uses & Applications:
Designed
with 50% Acid Resistance to Compete with Low Acid Resistant
Products
Sewer Shield® Liner 150 Trowelable is used as a
lining system for protection against chemical attack to
manholes, lift stations, headwork, sewer pipes, grit chambers,
clarifiers, wastewater and containment areas, walls, sumps,
trenches and pits. Due to the low odor and environmentally
friendly nature it is ideal for use as a protection system
in the wastewater and chemical industries.
Recommended for:
Manholes, Wet Wells, Grit Chambers, Headwork Channels, Clarifiers, Acid Containment, Thickeners, Sewer Piping, Floors, all areas exposed to Hydrogen Sulfide with lower acid resistent requirements than needed for Sewer Shield® 100
Colors:
Sewer Shield® 150 Trowelable
is supplied in the following colors: Beige. Special colors
are available upon request.
| Material Properties at 75 F. | |
| MIX RATIO, by volume | 2:1 |
| POT LIFE, 150 grams | 35 - 45 minutes |
| ASTM D4541, 7 Day Bond to damp Concrete |
Concrete Failure |
| ASTM D695, 7 Day Compressive Strength, psi |
8,500 |
| VOC | 0 GRAMS / LITER |
Surface Preparation:
Concrete must
be structurally sound, dry or damp, free of grease, oils,
coatings, dust, curing compounds and other contaminants.
Surface laitance must be removed. The preferred method of
surface preparation is abrasive blasting or shotblasting.
For oil contaminated surfaces use of steam cleaning in conjunction
with strong emulsifying detergent may be considered. Rinse
thoroughly with potable water. After cleaning, remove defective
concrete, honeycombs, cavities, joint crack voids and other
defects by routing to sound material. Smooth, precast and
formed concrete surfaces must be cleaned, roughened and
made absorptive by abrasive blasting or shotblasting. If
it is not possible to abrasive blast or shotblast, consider acid
etching with a 15% Hydrochloric acid solution. After etching
pressure wash or flush the surface with copious amounts
of water to neutralize the surface. Care must be taken to
ensure that all salts and residue from the reaction have
been removed. The pH of the surface should be checked as
per ASTM D4262 following acid etching. Following surface
preparation, the cleaned surface should pull concrete when
tested with an Elcometer or similar pull tester (ASTM D4541).
Before application of the lining system, use the "Visqueen
test" (ASTM D4263) to evaluate moisture level in concrete.
New Concrete:
Should be allowed to cure for a minimum of 28 days. (Consult
manufacturer if earlier times are required). Remove any
surface hardener or curing compounds, by using the recommended
mechanical methods for surface preparation. Prepare surfaces
as recommended above.
Procedures For New Concrete:
Old Concrete:
For quick, small patching use suitable epoxy mortar; for
larger areas, use cementatious patching materials, which
are compatible with the system. After patching, a light
brush blast is recommended prior to coating.
Procedures For Old Concrete:
Mixing Instructions:
Sewer Shield®
150 is available in pre-measured, pre-proportioned kits.
Pour the entire contents of Part B, into the Part
A, and mix thoroughly with a low speed drill and a
"Jiffy" mixer paddle. Mix for a minimum of 3 minutes. Scrape
the sides and bottom of the mixing container (including
the paddle of the mixer) during mixing. If the paddle is
too small or equipment is not adequate it will not give
a uniform mix and an incomplete cure will result together
with wet spots. Over mixing with a high-speed drill will
shorten the pot life as well as introduce excess air into
the mix. Mix only enough material that can be used within
the working life.
Coverage:
Coverage rates are approximate and for estimating purposes
only. Surface temperature, porosity, and texture will determine
actual material requirements.
Clean-Up Instructions:
Clean tools
and application equipment immediately after use with Methyl
Ethyl Ketone or Xylol. Clean spills or drips while still
wet with solvent. Dried material will require mechanical
abrasion for removal.
Packaging:
Sewer Shield® 150 Trowelable is available in kits. Storage:
50-90 degrees F. Protect from moisture and freezing. Shelf
Life: Two years in original, unopened containers, properly
stored.
| Standard MSDS Sheet | Standard Data Sheet |
Product Description:
C-120 Cement
is a specially formulated, fast setting, volume stable,
calcium aluminate cement based concrete and masonry patching
material requiring only the addition of potable water for
mixing. C-120 Cement may be used interior or exterior, above
or below grade on vertical, horizontal and overhead surfaces
without forms. After initial set, C-120 Cement may be shaved
to the contours of the surrounding area. C-120 Cement is
used to repair and protect against biogenic corrosion to
manholes, wet wells, lift stations, concrete pipe, and waste
water treatment plants. C-120 has high resistance to sewage,
extraordinary abrasion resistance and strong resistance
to biogenic corrosion by hydrogen sulfide (H2S) and sulfuric
acid (H2SO4) found in waste water environments. C-120 Cement
incorporates proprietary, fumed densifying agents enhancing
the product's ability to resist moist acidic conditions
allowing for prolonged life of finished surfaces. High alkalinity
of C-120 mortars will provide good rust protection. Also
excellent for the repair and protection of sidewalks, driveways,
expressways, ceilings, walls, curbs and panels. C-120 Cement
may be used for applications under constant moisture contact.
Benefits:
Composition:
Cement and selected aggregates.
| Setting Time: ASTM C-403 |
|
| Initial Set: | 12 minutes |
| Final Set: | 18 minutes |
| Yield Per 45# | .44 cubic feet |
| Compressive Strength: ASTM C-109 |
Split Tensile ASTM C-403 |
Shear Bond ATSM C-882 |
|
| 1 DAY | 5730 psi | ||
| 3 DAYS | 5950 psi | ||
| 7 DAYS | 6150 psi | 424 psi | 4210 psi |
| 28 DAYS | 7270 psi | 674 psi | 6530 psi |
| Freeze-Thaw Durability Factor: ASTM C-666 @ 300 Cycles: | 97.92 |
Directions For Use:
All areas to
be patched shall be clean and free of oil, grease, dirt,
deteriorated concrete and all contaminates. Undercut the
edges of the area to be patched to accommodate the repair.
C-120 Cement used to repair vehicular traffic bearing areas
should be placed a minimum of 1.5" in depth. Clean and prime
any exposed steel and reinforcing. Abrade or acid etch slick
surfaces to ensure proper bond. When the temperature is
above 40° F, pre-wet the prepared area with potable water
before applying C-120. Any excess water should be blown
or swept away to prevent dilution of the material.
C-120 Cement will require 3.25 to 3.5 quarts of potable water per 50 pound bag to achieve the proper mix consistency. Add the measured amount of C-120 to the proper amount of clean water and mix to a stiff putty like consistency for no more than four minutes. Mix small quantities of C-120 in a clean container with a hand trowel or in a wheelbarrow with a mud hoe. Use a rotary mixer with rubber tip blades for mixing larger quantities, up to 90 lbs. In deep areas over 2", C-120 may be extended with up to 25 pounds of clean, washed gravel per 50 pound bag for filler. Do not mix more material than can be placed in five minutes. Do not re-temper with additional water.
Place C-120 Cement immediately after mixing. Force C-120 firmly into the area to be patched by hand or with a trowel and mold to the desired shape. Compact thoroughly to ensure bond. After initial set, finish C-120 with a steel trowel until smooth and level with the surrounding surface. Do not overwork the material. Cure C-120 Cement with damp cure method if any surface treatment will be used. Curing is mandatory especially in hot weather, direct sunlight and for thin patches.
Cautions:
Mix C-120 no more than
four minutes. Do not mix more material than can be placed
in five minutes. Use only potable water for mixing. Do not
over water. Excess water does not improve workability. Do
not re-temper. Clean mixing equipment between batches. Do
not apply to frozen or frost filled surfaces. Do not apply
during freezing weather. Contains cement, avoid inhalation
of dust. Wear gloves during the mixing and placement of
material.
Packaging:
Fifty (50) pound (22.7
kg.) multiwall bleached paper bags. Fifty bags per pallet
(2,500 pounds per pallet)
Storage:
40° to 90° F
Shelf Life:
1 year in original unopened
package properly stored. Store in a dry location. Do not
lay bags directly on cement surfaces.
Freight Class:
Class 50
Limited Warranty:
This product is
warranted to be of merchantable quality when used according
to the instructions herein. It is not warranted to be suitable
for any purpose or use other than the general purpose for
which it is intended. Liability under this warranty is limited
to the replacement of the product as purchased, if found
to be defective upon inspection by the manufacturer. This
limited warranty is issued and accepted in lieu of all other
expressed warranties and explicitly excludes liability for
consequential damages. Buyer assumes all risk and liability
resulting from the use of this product.
| MSDS Sheet | Product Data |
Product Description:
Sewer Shield®
Cote is a 100% solids, USDA APPROVED, solvent free, low
odor, epoxy coating system, impervious to a wide variety
of acids, solvents, caustic solutions, oils, grease and
many other chemicals. Sewer Shield® Cote is specially formulated
in various setting times and with virtually no odor, making
it the ideal protection system for use in the food, dairy,
meat, beverage, brewery and chemical industries. Sewer Shield®
Cote when cured provides an impervious, hygienic, easy to
clean, glossy surface. Its unique formula, which incorporates
special adhesion promoters and stress relieving additives,
provides a tenacious bond to most surfaces including damp
concrete and also provides ample resilience to resist most
cracking from thermal or physical abuse. Sewer Shield® Cote
is excellent as a protection system to walls and floors
subject to light to medium traffic.
Application:
Sewer Shield® Cote can
be applied by roller, brush or spray with a coat thickness
of approximately 10 mils being possible in one application.
It's self-priming capabilities and tolerance for damp surfaces
offers the installer many labor saving steps as well as
less shut down time due to the fact that Sewer Shield® Cote
has very low odor and no solvent. No special precautions
are necessary to help contain any odor or solvent smell
often found in many other coating systems; even spraying
of Sewer Shield® Cote can be carried out with no solvent
added. Sewer Shield® Cote can be applied to concrete, wood,
metal, aluminum as well as stainless steel, without a primer.
Further advantages of Sewer Shield® Cote is that because
of its 100% solids formulation, it can be applied to floors
as a broadcast system either in solid colors or as a decorative
quartz or flake system, producing either a textured or smooth
finish.
Coverage:
Coverage is dependent on
the texture of the substrate. The average rate per gallon
is 160 square feet, which produces an approximate thickness
of 10 mils.
Setting Times:
Sewer Shield® Cote
is available in the following setting times:
Sewer Shield® Cote for normal ambient temperature. Sewer
Shield® Cote for FS (fast set) for fast setting times at
ambient temperature.
Sewer Shield® Cote XFS (extra fast
set) for extra fast setting times at ambient temperature.
Sewer Shield® Cote CS (cold set) for temperatures down to
45°F.
Sewer Shield® Cote XCS (extra cold set) for temperatures
down to 35°F.
Colors:
Sewer Shield® Cote is supplied
in the following colors: Grey, Dark Grey, Brick Red, Beige,
Green, Brown and White. Special colors are available upon
request.
Packaging and Mixing:
Sewer Shield®
Cote is supplied in either pre-measured packs or as a standard
pack (4 gallons) with a "user friendly" convenient easy
to mix ratio of two to one by volume (Part A to Part B).
Pour the contents of Part B into Part A and mix thoroughly
with either a low speed drill (700 rpm) or a bucket mixer
to uniform consistency for approximately one minute, making
sure the sides and bottom are scrapped. If a paddle is too
small, it will not give a uniform mix and an incomplete
cure will result together with wet spots. Over mixing with
a high-speed drill will shorten the pot life as well as
introduce excess air into the mix.
Priming:
Sewer Shield® Cote is self-priming;
however, priming is recommended to help seal the concrete
and reduce any out-gassing which creates bubbles in the
coating. Sealing of the concrete also produces a uniform
surface, which reduces excess absorption of the coating,
eliminating any "dry spots". Mechanically cleaned concrete
is invariably left with an "open" porous surface and priming
is highly recommended. Priming is done with either Corro-Prime,
which is a 100% solids primer, or with Corro Aqua-Prime,
which is a water-based primer. For rough open surfaces use
Corro-Prime and for a smooth dense surface use Corro-Aqua-Prime.
However, if Sewer Shield® Cote is going to be applied over
"green" concrete, then our Corro-Cure (a slow set primer)
must be used first. See Corro-Prime data sheet.
| MSDS Sheet | Product Data |
Product Description:
Special Features:
Application:
Packaging:
Sewer Shield Caulk is
available in the following pak sizes:
One Quart
One-Half Gallon
One Gallon
Coverage: (Linear Feet Per Gallon)
| Depth of Joint | Width of Joint | ||||||
| 1/4" | 3/8" | 1/2" | 5/8" | 3/4" | 7/8" | 1" | |
| 1/4" | 320 | 213 | 160 | 128 | 107 | 91 | 80 |
| 3/8" | 213 | 142 | 107 | 85 | 71 | 61 | 53 |
| 1/2" | 160 | 107 | 80 | 64 | 53 | 46 | 40 |
Priming:
Priming is not necessary,
however, if after cutting open an expansion joint or crack
the edges appear to be dusting, then the application of
Corro-Prime is advised. Cutting of the joints or cracks
must be done with a diamond blade as a fiber blade is likely
to leave a "black smudge" on the surface which will interfere
with the adhesion of the caulk.
Set Times:
Sewer Shield® Caulk is
available in various setting times. For quick reference,
the following guide is given for the different temperature
applications:
Sewer Shield® Caulk - About 5 hours
at 73°F.
Sewer Shield® Caulk F.S. (Fast Set) About 3
hours at 73°F.
Sewer Shield® Caulk X.F.S. (Extra Fast
Set) - About 1 ½ hours at 73°F.
Sewer Shield® Caulk C.S.
(Cold Set)- About 16 hours at 40°F.
Mixing and Application:
Mix Part
A with Part B and apply with a caulking gun or putty knife.
Detailed mixing and application instructions are available
upon request.
Colors:
Black, White, Gray, Dark
Gray, Brick Red, Beige, Green and Brown. Special colors,
such as Stainless Steel, are available upon request, for
an additional charge.
Clean Up:
Sewer Shield® Caulk while
still wet can be cleaned up with warm soapy water, but if
allowed to set then mechanical cleaning or the application
of a very strong paint stripper will have to be used.
Precautions:
As with all epoxies,
good hygienic habits must be observed and the wearing of
protective clothing and gloves is advised. Before using
any of the products, please read their respective safety
data sheets.
Physical Characteristics:
Mixing
Ratio By Volume
A:B
8:1
Density:
Part A: 9.32 lbs./gallon
Part B: 8.19 lbs./gallon
A & B Mixed: 9.2 lbs./gallon
Warranty:
The data, statements and
recommendations set forth in this product information sheet
are based on testing, research and other development work
which has been carefully conducted by us, and we believe
such data, statements and recommendations will serve as
reliable guidelines. However, this product is subject to
numerable uses under varying conditions over which we have
no control, and accordingly, we do NOT warrant that this
product is suitable for any particular use. Users are advised
to test the product in advance to make certain it is suitable
for their particular production conditions and particular
use or uses.
WARRANTY - All products manufactured by us are warranted to be first class material and free from defects in material and workmanship. Liability under this warranty is limited to the net purchase price of any such products proven defective or, at our option, to the repair or replacement of said products upon their return to us transportation prepaid. All claims hereunder on defective products must be made in writing within 30 days after the receipt of such products in your plant and prior to further processing or combining with other materials and products. WE MAKE NO WARRANTY. EXPRESS OR IMPLIED, AS TO THE SUITABILITY OF ANY OF OUR PRODUCTS FOR ANY PARTICULAR USE, AND WE SHALL NOT BE SUBJECT TO LIABILITY FROM ANY DAMAGES RESULTING FROM THEIR USE IN OPERATIONS NOT UNDER OUR DIRECT CONTROL.
THIS WARRANTY IS EXCLUSIVE OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND NO REPRESENTATIVE OF OURS OR ANY OTHER PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF OUR PRODUCTS.
| MSDS Sheet | Product Data |
Product Description:
Special Features:
Application:
Colors:
Black, White, Ivory, Gray,
Dark Gray, Brick Red, Beige, Green and Brown. Special colors
are available upon request, for an additional charge.
Precautions:
As with all epoxies,
good hygienic habits must be observed and the wearing of
protective clothing and gloves is advised. Before using
this product, please read the material safety data sheet.
| Set Times (Slab Temperature) |
50° F | 73° F | 90° F |
| Pot Life | 1 Hour | 45 minutes | 25 minutes |
| Recoat Time - Floors | 18 Hours | 15 hours | 12 Hours |
| Recoat Time - Walls | 12 Hours | 9 hours | 6 Hours |
| Foot Traffic | 18 Hours | 15 hours | 12 Hours |
| Forklift Traffic | 72 Hours | 48 hours | 24 Hours |
| Full Chemical Resistance* | 9 Days | 7 days | 5 Days |
| ASTM | TEST METHOD @ 73° F | Results |
| C579 | Compressive Strength | 5946 psi |
| C579 | Percent Compressive Resiliency | 42.73% |
| C579 | Compressive Strength @ Yield | 1608 psi |
| C579 | Percent Compressive Resiliency @ Yield | 6.36% |
| C580 | Flexural Strength | 2700 psi |
| C580 | Flexural Modulus of Elasticity | 1,43 x 10 (5th power) |
| C307 | Tensile Strength | 1500 psi |
| C307 | Percent Tensile Elongation | 15.51% |
| C321 | Bond Strength to Concrete | Failure in Concrete |
| C884 | Thermal Compatibility to Concrete | Pass |
Warranty:
All products manufactured
by us are warranted to first class material and free from
defects in material and workmanship. Liability under this
warranty is limited to the net purchase price of any such
products proven defective, or, at our option, to the repair
or replacement of said products upon their return to us
transportation prepaid. All claims hereunder on defective
products must be made in writing within 30 days after the
receipt of such products in your plant and prior to further
processing or combining with other materials and products.
WE MAKE NO WARRANTY, EXPRESS OR IMPLIED, AS TO THE SUITABILITY
OF ANY OF OUR PRODUCTS FOR ANY PARTICULAR USE, AND WE SHALL
NOT BE SUBJECT TO LIABILITY FROM ANY DAMAGES RESULTING FROM
THEIR USE IN OPERATIONS NOT UNDER OUR DIRECT CONTROL.
THIS WARRANTY IS EXCLUSIVE OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND NO REPRESENTATIVE OF OURS OR ANY OTHER PERSON IS AUTHORIZED TO ASSUME FOR US ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF OUR PRODUCTS.
| EC Grout MSDS Sheet | Product Data |
| Accelerant MSDS Sheet |
Product Description
Environmental Coatings Flexible Grout is a multi-purpose injection resin designed to
seal leaking cracks, voids or fractures in concrete structures.
The single component system utilizes an accelerator to
"adjust" the reaction profile as needed for job site conditions.